IM-DB 9

im-db-9
Category IEC/EN C1/C2/C3
Nominal operating voltage: Un: 12Vdc
Max. operating voltage: Uc: 15Vdc
Frequency range: 1MHz
Surge discharge rating: In:1kA; Imax:2kA
Series load current: 500mA
Termination: DB 9 male – DB 9 female
Housing: In-line compact design
Complies with: IEC/EN 61643-21

Specifikacija proizvoda

Tehnical data
Type IM-DB 9
Elecrtical characteristics  
Number of preotected pairs 8
Nominal operating voltage (DC) Un 12V
Max.continuous operating voltage (DC) Uc 15V
Nominal discharge current (8/20μs) In (line-line) 100A
(lines-PG) 1kA
Max. discharge current (8/20μs) Imax (line-line) 200A
(lines-PG) 2kA
Protection level at In  Up (line-line) ≤30V
(line-PG) ≤200V
Protection level at 1kV/μs  Up (line-line) ≤24V
(line-PG) ≤30V
Response time of overvoltage protection tA <1ns
Transverse capacitance C (line-line) 600pF
(lines-PG) 700pF
Limited frequency fG 500kHz
Mechanical characteristics
Connection 9 pole M/F
Termination DB 9 male – DB 9 female
Temperatur range -40˚C…+80˚C
Degree of protection IEC/EN 60529 IP20
Housing material Thermoplastic; extinguishing degree UL 94 V-0
Ordering information
Un 12V
Ordering code IM-DB 9 127526